PLCs Horn & Target           Motion Control Controls Target, Baffle & Horn Instrumentation CATV, Network & Safety Safety Horn                             Power Supply Horn                             Power Supply Unassigned Unassigned
THSR 101  7Ft THSR 102  7Ft THSR 103  7Ft THSR 104  7Ft THSR 105  7Ft End THSR 106  7Ft THSR 107  7Ft THSR 108  7Ft THSR 109  7Ft
Rack
  Analog Entry Box            16B & 48T Analog Entry Box           32B & 32T Multichannel Low Frequency Noise Abatement
                                                       
1     1     1 BP Input Patch FT   1 BP Input Patch FT   1 3U Blank     1 Fiber Optic Fanout   1     1     1    
2     2     2 NuMI BP Input          CC $E6 N20   2 NuMI BP Input          CC $E6 N21   2     2   2     2     2    
3     3     3   3   3     3   3     3     3    
4     4     4 MADC #87                    14 Bit   4 MADC #88                    14 Bit   4 CATV Monitors     4 Single Channel Current Driver Power Supply Fanout   4     4     4    
5     5     5   5   5     5   5     5     5    
6     6     6   6   6     6   6     6     6    
7     7     7 Process              Channel              Interface                        MADC #87   7 Process              Channel              Interface                        MADC #88   7     7 H2O Interlock Fanout   7     7     7    
8     8     8   8   8     8 Safety Relay              Chassis   8     8     8    
9     9     9   9   9     9   9     9     9    
10     10     10   10   10 2U Blank     10   10     10     10    
11     11     11     11     11     11 Oscilloscope   11     11     11    
12     12     12     12     12 ACNET Console        14U     12   12     12     12    
13     13     13     13     13     13   13     13     13    
14     14     14     14     14     14   14     14     14    
15     15     15 TTL Fanout   15     15     15 Temperature Monitor   15     15     15    
16 Reserved   16     16 Patch Feedthru   16     16     16 Drawer   16     16     16    
17 for   17     17 CAMAC Crate      Address $E6   17     17     17   17 Reserved    17     17    
18 PLCs   18     18   18 1U Blank   18     18 Feedthru Panel   18 for Bourkland   18     18    
19     19     19   19 NIM Bin   19     19 Control Chassis   19     19     19    
20 Baffle & Targt Instr   20     20   20   20     20   20 Personal Computer   20     20    
21 Hrn & Hrn SL Instr   21 1U Blank   21   21   21     21   21 Spares   21     21    
22 Tgt & Baffle RAW   22 Motion Control                             VME Crate   22   22   22     22   22     22     22    
23 Horn 1 RAW   23   23   23   23     23   23     23     23    
24 Horn 2 RAW   24   24 1U Blank   24 Patch Panel FT   24     24   24     24     24    
25 Intrm Cool H1 & H2   25 1U Blank   25 3U Blank   25     25     25   25     25     25    
26 Decay Pipe RAW   26 Motion Interface Chassis   26   26     26 1U Blank     26   26     26     26    
27 Target Pile Air Cool   27   27   27     27 Controls & Network           SM & MM Fiber Optic Distr Shelf     27   27     27     27    
28     28 1U Blank   28 3U Blank   28     28     28 Filtered Fan   28     28     28    
29     29 Target                               High Current Motor Driver Chassis   29   29     29     29   29     29     29    
30     30   30   30     30     30 IRM   30     30     30    
31     31   31 Controls                  Fiber Optic                  Repeaters   31     31 1U Blank     31 Internet Rack                Monitor   31     31     31    
32     32   32   32     32 24 Port Ethernet Sw     32   32     32     32    
33     33 1U Blank   33   33     33 Feedthru Trough     33   33     33     33    
34     34 Horn                                    High Current Motor Driver Chassis   34   34     34 1U Blank     34 1U Blank   34     34     34    
35     35   35 1U Blank   35     35 Reserved for Radiation Monitor Chassis     35 +/- 15 Volt                              Bulk Power Supply   35     35     35    
36     36   36     36     36     36   36     36     36    
37     37   37     37     37     37   37     37     37    
38     38 1U Blank   38     38     38     38 + 24 Volt   38     38     38    
39     39 Motor Power Supply Chassis   39     39     39 SSIU for NuMI RSS     39 +/- 15 Volt   39     39     39    
40     40   40     40     40     40 + 5 Volt   40     40     40    
41     41   41 Loss Monitor    Chassis #4   41 Loss Monitor    Chassis #5   41 UPS for NuMI RSS     41 Power Supplies   41     41     41    
42     42   42   42   42     42 Fan Tray   42     42     42    
43     43   43   43   43     43 Rack Air Filter   43     43     43    
44     44 Duplex Outlet Strip   44 2U Blank   44 Duplex Outlet Strip   44     44   44 Duplex Outlet Strip   44     44 Duplex Outlet Strip  
45     45 1U Blank   45   45 1U Blank   45 1U Blank     45   45 1U Blank   45     45 1U Blank  
                                                       
<-----   RAW Room & North Shaft & South   ----> <-------  West Target Hall & East  ------>