CATV Controls Links
MI60 218  7Ft MI60 219  7Ft MI60 226  7Ft MI60 227  7Ft MI60 203  7Ft MI60 209  7 Ft
Analog Entry Box      32T  16B  16T Analog Entry Box         32B  32T
                                   
1 3U Blank   1 BP Input Patch FT   1 MADC #44                    12 Bit   1 BP Input Patch FT   1 Patch Panel FT   1 ARCNET Hub  
2   2 NuMI BP Input        CC $73 N22   2   2 NuMI BP Input        CC $70 N19   2 DCCT for HV101   2  
3   3   3   3   3   3 ARCNeT Patch Panel  
4 Profile Monitor     E:PM101                 (SWIC Controller)   4 MADC #38               14 Bit   4   4 BP Input Patch FT   4   4 SWIC Controller  
5   5   5 Process             Channel                 Interface                MADC #44   5 Recycler BP Input   5 Current Regulator     for HV101   5  
6   6   6   6   6   6  
7 1U Blank   7 Process             Channel                 Interface                MADC #38   7   7 1U Blank   7   7 1U Blank  
8 Profile Monitor      E:PM105                 (SWIC Controller)   8   8   8 BP Input Patch FT   8 BULB for HV101   8 SWIC Controller  
9   9   9 1U Blank   9 Main Inj BP Input   9   9  
10   10   10 CATV Monitors   10   10 1U Blank   10  
11 1U Blank   11 1U Blank   11   11 1U Blank   11 NuMI Reserved         VME Crate               for 13 Beam                      Position Monitors                                           9U   11 1U Blank  
12 ACNET Console                     14U   12 TTL Fanout   12   12 TTL Fanout   12   12 SWIC Controller  
13   13 1U Blank   13   13 1U Blank   13   13  
14   14 CAMAC Crate      Address $73   14   14 CAMAC Crate      Address $70   14   14  
15   15   15   15   15   15 1U Blank  
16   16   16 1U Blank   16   16   16 SWIC Controller  
17   17   17 CATV Modulator   17   17   17  
18   18   18 1U Blank   18   18   18  
19   19   19 CATV Modulator   19   19   19 1U Blank  
20   20   20 1U Blank   20   20 1U Blank   20 SWIC Controller  
21   21 Patch Panel FT   21 CATV Modulator   21 1U Blank   21 MECAR           Diagnostic                 Console                       14U                         (Kevin Martin)            (Relocated Down)   21  
22   22 NIM Bin                          3 of 12 Slots Used       6 Slots Reserved for PM Clearing Voltage Supplies   22 2U Blank   22 Controls                  Fiber Optic                  Distribution Shelf   22   22  
23   23   23   23   23   23 1U Blank  
24   24   24 Loss Monitor    Chassis #1   24   24   24 SWIC Controller  
25   25   25   25   25   25  
26 ARCNeT Patch Panel   26   26   26 2U Blank   26   26  
27 ARCNET Hub   27 1U Open   27 1U Blank   27   27   27 1U Blank  
28   28 2U Blank   28 Loss Monitor    Chassis #2   28 Controls                  Fiber Optic                  Repeaters   28   28 Multiwire/SWIC Motor Controller  
29 1U Blank   29   29   29   29   29  
30 Profile Monitor      E:PM107                   (SWIC Controller)   30 2U Blank   30   30   30   30  
31   31   31 4U Open   31   31   31  
32   32 6U Blank                    Reserved Space for New Profile Monitor Motion Control   32   32 4U Blank   32   32 1U Blank  
33 1U Blank   33   33   33   33   33 Profile Mon/SWIC Motor Controller         Two Free Channels  
34 Profile Monitor      E:PM108                  (SWIC Controller)   34   34   34   34   34  
35   35   35 Patch Panel   35   35     35  
36   36   36 VME Crate   36 7U Blank   36     36  
37 1U Blank   37   37   37   37     37 1U Blank  
38 Profile Monitor       E:PM112                  (SWIC Controller)   38 8U Blank                    Reserved Space for New Profile Monitor Motion Control   38   38   38 Miscellaneous   38 2U Blank  
39   39   39   39   39 Equipment   39  
40   40   40   40   40 and Debris   40 6U Blank  
41 5U Blank                    Reserved Space for New Profile Monitor Motion Control   41   41   41   41 Below Console   41  
42   42   42   42   42     42  
43   43   43   43 1U Blank   43     43  
44   44   44   44 Duplex Outlet Strip   44     44  
45   45   45 1U Open   45 1U Blank   45     45